    摘要:

    针对基于信号到达相位差(Phase difference of arrival, PDOA)双频比相法测距方案频率选取随机性大,导致测距结果精度低等缺点,提出了一种基于频域的信号到达相位差(Phase difference of arrival in frequency domain ,FD-PDOA)双频比相法测距方案。结合最小二乘法以及一次线性回归的思想,建立了测距的数学模型。利用Matlab对实验数据进行仿真分析表明:在0.5 m和1.0 m处,若采用PDOA双频比相法测距方案,误差分别在50%和30%上下浮动;采用FD-PDOA双频比相法测距方案,从整体上分析相位差值的变化特性,误差在10%上下浮动,进一步提升了测距精度。

    Abstract:

    To overcome the drawbacks of phase difference of arrival (PDOA)dual-frequency comparison ranging method, i.e. large frequency selection random and low measuring distance accuracy, the phase difference of arrival in frequency domain (FD-PDOA) dual-frequency comparison ranging method is proposed. Combining with the least square method and linear regression, a mathematic model is built to measure the distance. Simulation results show that the measurement error of PDOA dual-frequency comparison ranging method floats at 50% and 30% at distance 0.5 m and 1.0 m respectively, while the measurement error of FD-PDOA dual-frequency comparison ranging method is reduced to 10% through an overall analysis of the phase difference change characteristics, and the method considerably improve the measuring distance accuracy.